Перевод: с французского на русский

с русского на французский

operating times

  • 1 cycle de manoeuvres (d'un appareil mécanique de connexion)

    1. цикл срабатываний

     

    цикл срабатываний контактного коммутационного аппарата
    Последовательность переходов из одного положения в другое и обратно в первое через все прочие положения, если они имеются.
    МЭК 60050(441-16-02).
    [ ГОСТ Р 50030. 1-2000 ( МЭК 60947-1-99)]


    цикл оперирования 1)
    -
    [IEV number 442-01-50]

    EN

    operating cycle (of a mechanical switching device)
    a succession of operations from one position to another and back to the first position through all other positions, if any
    [IEV number 441-16-02]


    operating cycle
    a succession of operations from one position to another and back to the first position
    Source: 441-16-02 MOD
    [IEV number 442-01-50]

    FR

    cycle de manoeuvres (d'un appareil mécanique de connexion)
    suite de manoeuvres d'une position à une autre avec retour à la première position en passant par toutes les autres positions, s'il en existe
    [IEV number 441-16-02]


    cycle de manoeuvres
    suite de manoeuvres d'une position à une autre et retour à la première position
    Source: 441-16-02 MOD
    [IEV number 442-01-50]

    1)   правильно - цикл срабатываний
    [Интент]

    См. также коммутационный цикл

    Тематики

    • аппарат, изделие, устройство...

    Синонимы

    EN

    DE

    FR

    Франко-русский словарь нормативно-технической терминологии > cycle de manoeuvres (d'un appareil mécanique de connexion)

  • 2 séquence de manoeuvres (d'un appareil mécanique de connexion)

    1. последовательность срабатываний контактного коммутационного аппарата

     

    последовательность срабатываний контактного коммутационного аппарата
    Последовательность установленных срабатываний с заданными интервалами времени.
    МЭК 60050(441-16-03).
    [ ГОСТ Р 50030. 1-2000 ( МЭК 60947-1-99)]

    EN

    operating sequence (of a mechanical switching device)
    a succession of specified operations with specified time intervals
    [IEV number 441-16-03]

    FR

    séquence de manoeuvres (d'un appareil mécanique de connexion)
    suite de manoeuvres spécifiées effectuées à des intervalles de temps spécifiés
    [IEV number 441-16-03]

    Тематики

    • аппарат, изделие, устройство...

    EN

    DE

    FR

    Франко-русский словарь нормативно-технической терминологии > séquence de manoeuvres (d'un appareil mécanique de connexion)

  • 3 tension assignée

    1. номинальное напряжение

     

    номинальное напряжение
    Напряжение, установленное изготовителем для прибора
    [ ГОСТ Р 52161. 1-2004 ( МЭК 60335-1: 2001)]

    номинальное напряжение Uном, кВ
    Номинальное междуфазное напряжение электрической сети, для работы в которой предназначены коммутационные аппараты.
    [ ГОСТ Р 52726-2007]

    номинальное напряжение

    Un
    Напряжение, применяемое для обозначения или идентификации системы электроснабжения.
    [ ГОСТ Р 51317.4.30-2008 (МЭК 61000-4-30:2008)]

    EN

    rated voltage
    voltage assigned to the appliance by the manufacturer
    [IEC 60335-1, ed. 4.0 (2001-05)]

    rated voltage
    quantity value assigned, generally by the manufacturer, for a specified operating condition of a machine
    [IEC 60034-18-41, ed. 1.0 (2006-10)]

    rated voltage
    input or output supply voltage for which equipment is designed or specified
    [IEC 88528-11, ed. 1.0 (2004-03)]

    rated voltage
    specified value of the voltage at the terminals of the machine when operating at a rating. If unidirectional, the voltage is the arithmetic mean of the recurring waveform and if alternating it is the root mean square value of the fundamental frequency component of the recurring waveform
    NOTE - In the case of a machine with a protective resistor permanently in series, the resistor is considered as an integral part of the machine
    [IEC 60349-1, ed. 1.0 (1999-11)]

    rated voltage
    the value of voltage assigned by the manufacturer to a component, device or equipment and to which operation and performance characteristics are referred
    NOTE - Equipment may have more than one rated voltage value or may have a rated voltage range.
    [IEC 62497-1, ed. 1.0 (2010-02)]

    rated voltage
    reference voltage for which the cable is designed, and which serves to define the electrical tests
    NOTE 1 - The rated voltage is expressed by the combination of two values: Uo/U expressed in volts (V):
    Uo being the r.m.s. value between any insulated conductor and "earth" (metal covering of the cable or the surrounding medium);
    U being the r.m.s. value between any two phase conductors of a multicore cable or of a system of single-core cables.
    In an alternating-current system, the rated voltage of a cable is at least equal to the nominal voltage of the system for which it is intended.
    This condition applies both to the value Uo and to the value U.
    In a direct current system, the nominal voltage of the system is not higher than 1,5 times the rated voltage of the cable.
    NOTE 2 - The operating voltage of a system may permanently exceed the nominal voltage of such a system by 10 %. A cable can be used at a 10 % higher operating voltage than its rated voltage if the latter is at least equal to the nominal voltage of the system
    [IEC 60245-1, ed. 4.0 (2003-12)]

    rated voltage
    highest allowable voltage between the conductors in a twin and multi conductor cable, or between one conductor and an electrical conductive screen, or between the two ends of a single core cable, or earth in unscreened cables
    [IEC 60800, ed. 3.0 (2009-07)]

    rated voltage
    the r.m.s. line-to-line voltage under rated conditions
    Primary side of input transformer: ULN
    Converter input: UVN
    Converter output: UaN
    Motor voltage: UAN
    [IEC 61800-4, ed. 1.0 (2002-09)]

    rated voltage
    input or output voltage (for three-phase supply, the phase-to-phase voltage) as declared by the manufacturer
    [IEC 62040-1, ed. 1.0 (2008-06)]

    nominal voltage, Un
    voltage by which a system is designated or identified
    [IEC 61000-4-30, ed. 2.0 (2008-10)]

    FR

    tension assignée
    tension attribuée à l'appareil par le fabricant
    [IEC 60335-1, ed. 4.0 (2001-05)]

    tension nominale
    tension assignée, généraleme<>value of voltage assigned by the manufacturer, to a componentnt par le constructeur pour des conditions spécifiées de fonctionnement de la machine
    [IEC 60034-18-41, ed. 1.0 (2006-10)]

    tension assignée
    tension spécifiée aux bornes de la machine quand celle-ci fonctionne au régime assigné. Dans le cas d'une tension redressée, sa valeur est égale à la valeur moyenne de l'onde périodique. Dans le cas d'une tension alternative, sa valeur est égale à la valeur efficace de la composante fondamentale de l'onde périodique
    NOTE - Dans le cas d'une machine équipée d'une résistance de protection connectée en permanence en série, la résistance est considérée comme faisant partie intégrante de la machine
    [IEC 60349-1, ed. 1.0 (1999-11)]

    tension assignée
    valeur de la tension, assignée par le constructeur à un composant, à un dispositif ou à un matériel, et à laquelle on se réfère pour le fonctionnement et pour les caractéristiques fonctionnelles
    NOTE - Les matériels peuvent avoir plusieurs valeurs ou une plage de tensions assignées.
    [IEC 62497-1, ed. 1.0 (2010-02)]

    tension assignée
    tension de référence pour laquelle le conducteur ou le câble est prévu et qui sert à définir les essais électriques
    NOTE 1 - La tension assignée est exprimée par la combinaison de deux valeurs Uo /U, exprimées en volts (V):
    Uo étant la valeur efficace entre l'âme d'un conducteur isolé quelconque et la «terre» (revêtement métallique du câble au milieu environnant);
    U étant la valeur efficace entre les âmes conductrices de deux conducteurs de phase quelconques d'un câble multiconducteur ou d'un système de câbles monoconducteurs ou de conducteurs.
    Dans un système à courant alternatif, la tension assignée d'un conducteur ou d’un câble est au moins égale à la tension nominale du système pour lequel il est prévu.
    Cette condition s'applique à la fois à la valeur Uo et à la valeur U.
    Dans un système à courant continu, la tension nominale admise du système n’est pas supérieure à 1,5 fois la tension assignée du conducteur ou du câble.
    NOTE 2 - La tension de service d'un système peut en permanence dépasser la tension nominale dudit système de 10 %. Un conducteur ou un câble peut être utilisé à une tension de service supérieure de 10 % à sa tension assignée si cette dernière est au moins égale à la tension nominale du système
    [IEC 60245-1, ed. 4.0 (2003-12)]

    tension assignée
    tension maximale admissible entre les âmes dans un câble ayant une paire ou multi conducteur ou entre une âme et un écran conducteur électrique ou avec la terre pour un câble non écranté ou encore entre les deux extrémités d’un câble à âme unique
    [IEC 60800, ed. 3.0 (2009-07)]

    tension assignée
    valeur efficace de la tension de ligne (entre phases) dans les conditions assignées
    Primaire du transformateur d’entrée: ULN
    Entrée du convertisseur: UVN
    Sortie du convertisseur: UaN
    Moteur: UAN
    [IEC 61800-4, ed. 1.0 (2002-09)]

    tension assignée
    tension d’alimentation d’entrée ou de sortie (dans le cas d’une alimentation triphasée, tension entre phases) déclarée par le constructeur
    [IEC 62040-1, ed. 1.0 (2008-06)]

    tension nominale, Un
    tension par laquelle un réseau est désigné ou identifié
    [IEC 61000-4-30, ed. 2.0 (2008-10)]

    Тематики

    Синонимы

    • Un

    EN

    FR

    Франко-русский словарь нормативно-технической терминологии > tension assignée

  • 4 tension nominale

    1. номинальное напряжение конденсатора
    2. номинальное напряжение

     

    номинальное напряжение
    Напряжение, установленное изготовителем для прибора
    [ ГОСТ Р 52161. 1-2004 ( МЭК 60335-1: 2001)]

    номинальное напряжение Uном, кВ
    Номинальное междуфазное напряжение электрической сети, для работы в которой предназначены коммутационные аппараты.
    [ ГОСТ Р 52726-2007]

    номинальное напряжение

    Un
    Напряжение, применяемое для обозначения или идентификации системы электроснабжения.
    [ ГОСТ Р 51317.4.30-2008 (МЭК 61000-4-30:2008)]

    EN

    rated voltage
    voltage assigned to the appliance by the manufacturer
    [IEC 60335-1, ed. 4.0 (2001-05)]

    rated voltage
    quantity value assigned, generally by the manufacturer, for a specified operating condition of a machine
    [IEC 60034-18-41, ed. 1.0 (2006-10)]

    rated voltage
    input or output supply voltage for which equipment is designed or specified
    [IEC 88528-11, ed. 1.0 (2004-03)]

    rated voltage
    specified value of the voltage at the terminals of the machine when operating at a rating. If unidirectional, the voltage is the arithmetic mean of the recurring waveform and if alternating it is the root mean square value of the fundamental frequency component of the recurring waveform
    NOTE - In the case of a machine with a protective resistor permanently in series, the resistor is considered as an integral part of the machine
    [IEC 60349-1, ed. 1.0 (1999-11)]

    rated voltage
    the value of voltage assigned by the manufacturer to a component, device or equipment and to which operation and performance characteristics are referred
    NOTE - Equipment may have more than one rated voltage value or may have a rated voltage range.
    [IEC 62497-1, ed. 1.0 (2010-02)]

    rated voltage
    reference voltage for which the cable is designed, and which serves to define the electrical tests
    NOTE 1 - The rated voltage is expressed by the combination of two values: Uo/U expressed in volts (V):
    Uo being the r.m.s. value between any insulated conductor and "earth" (metal covering of the cable or the surrounding medium);
    U being the r.m.s. value between any two phase conductors of a multicore cable or of a system of single-core cables.
    In an alternating-current system, the rated voltage of a cable is at least equal to the nominal voltage of the system for which it is intended.
    This condition applies both to the value Uo and to the value U.
    In a direct current system, the nominal voltage of the system is not higher than 1,5 times the rated voltage of the cable.
    NOTE 2 - The operating voltage of a system may permanently exceed the nominal voltage of such a system by 10 %. A cable can be used at a 10 % higher operating voltage than its rated voltage if the latter is at least equal to the nominal voltage of the system
    [IEC 60245-1, ed. 4.0 (2003-12)]

    rated voltage
    highest allowable voltage between the conductors in a twin and multi conductor cable, or between one conductor and an electrical conductive screen, or between the two ends of a single core cable, or earth in unscreened cables
    [IEC 60800, ed. 3.0 (2009-07)]

    rated voltage
    the r.m.s. line-to-line voltage under rated conditions
    Primary side of input transformer: ULN
    Converter input: UVN
    Converter output: UaN
    Motor voltage: UAN
    [IEC 61800-4, ed. 1.0 (2002-09)]

    rated voltage
    input or output voltage (for three-phase supply, the phase-to-phase voltage) as declared by the manufacturer
    [IEC 62040-1, ed. 1.0 (2008-06)]

    nominal voltage, Un
    voltage by which a system is designated or identified
    [IEC 61000-4-30, ed. 2.0 (2008-10)]

    FR

    tension assignée
    tension attribuée à l'appareil par le fabricant
    [IEC 60335-1, ed. 4.0 (2001-05)]

    tension nominale
    tension assignée, généraleme<>value of voltage assigned by the manufacturer, to a componentnt par le constructeur pour des conditions spécifiées de fonctionnement de la machine
    [IEC 60034-18-41, ed. 1.0 (2006-10)]

    tension assignée
    tension spécifiée aux bornes de la machine quand celle-ci fonctionne au régime assigné. Dans le cas d'une tension redressée, sa valeur est égale à la valeur moyenne de l'onde périodique. Dans le cas d'une tension alternative, sa valeur est égale à la valeur efficace de la composante fondamentale de l'onde périodique
    NOTE - Dans le cas d'une machine équipée d'une résistance de protection connectée en permanence en série, la résistance est considérée comme faisant partie intégrante de la machine
    [IEC 60349-1, ed. 1.0 (1999-11)]

    tension assignée
    valeur de la tension, assignée par le constructeur à un composant, à un dispositif ou à un matériel, et à laquelle on se réfère pour le fonctionnement et pour les caractéristiques fonctionnelles
    NOTE - Les matériels peuvent avoir plusieurs valeurs ou une plage de tensions assignées.
    [IEC 62497-1, ed. 1.0 (2010-02)]

    tension assignée
    tension de référence pour laquelle le conducteur ou le câble est prévu et qui sert à définir les essais électriques
    NOTE 1 - La tension assignée est exprimée par la combinaison de deux valeurs Uo /U, exprimées en volts (V):
    Uo étant la valeur efficace entre l'âme d'un conducteur isolé quelconque et la «terre» (revêtement métallique du câble au milieu environnant);
    U étant la valeur efficace entre les âmes conductrices de deux conducteurs de phase quelconques d'un câble multiconducteur ou d'un système de câbles monoconducteurs ou de conducteurs.
    Dans un système à courant alternatif, la tension assignée d'un conducteur ou d’un câble est au moins égale à la tension nominale du système pour lequel il est prévu.
    Cette condition s'applique à la fois à la valeur Uo et à la valeur U.
    Dans un système à courant continu, la tension nominale admise du système n’est pas supérieure à 1,5 fois la tension assignée du conducteur ou du câble.
    NOTE 2 - La tension de service d'un système peut en permanence dépasser la tension nominale dudit système de 10 %. Un conducteur ou un câble peut être utilisé à une tension de service supérieure de 10 % à sa tension assignée si cette dernière est au moins égale à la tension nominale du système
    [IEC 60245-1, ed. 4.0 (2003-12)]

    tension assignée
    tension maximale admissible entre les âmes dans un câble ayant une paire ou multi conducteur ou entre une âme et un écran conducteur électrique ou avec la terre pour un câble non écranté ou encore entre les deux extrémités d’un câble à âme unique
    [IEC 60800, ed. 3.0 (2009-07)]

    tension assignée
    valeur efficace de la tension de ligne (entre phases) dans les conditions assignées
    Primaire du transformateur d’entrée: ULN
    Entrée du convertisseur: UVN
    Sortie du convertisseur: UaN
    Moteur: UAN
    [IEC 61800-4, ed. 1.0 (2002-09)]

    tension assignée
    tension d’alimentation d’entrée ou de sortie (dans le cas d’une alimentation triphasée, tension entre phases) déclarée par le constructeur
    [IEC 62040-1, ed. 1.0 (2008-06)]

    tension nominale, Un
    tension par laquelle un réseau est désigné ou identifié
    [IEC 61000-4-30, ed. 2.0 (2008-10)]

    Тематики

    Синонимы

    • Un

    EN

    FR

     

    номинальное напряжение конденсатора
    Максимальное напряжение, при котором конденсатор может работать в течение минимальной наработки в условиях, указанных в нормативно-технической документации
    [ ГОСТ 21415-75]

    номинальное напряжение конденсатора
    Действующее значение синусоидального переменного напряжения при номинальной частоте, на которое рассчитан конденсатор. Номинальное напряжение многофазного конденсатора - значение напряжения между выводами.
    [ ГОСТ 1282-88]

    Тематики

    EN

    DE

    FR

    Франко-русский словарь нормативно-технической терминологии > tension nominale

  • 5 Un

    1. номинальное напряжение

     

    номинальное напряжение
    Напряжение, установленное изготовителем для прибора
    [ ГОСТ Р 52161. 1-2004 ( МЭК 60335-1: 2001)]

    номинальное напряжение Uном, кВ
    Номинальное междуфазное напряжение электрической сети, для работы в которой предназначены коммутационные аппараты.
    [ ГОСТ Р 52726-2007]

    номинальное напряжение

    Un
    Напряжение, применяемое для обозначения или идентификации системы электроснабжения.
    [ ГОСТ Р 51317.4.30-2008 (МЭК 61000-4-30:2008)]

    EN

    rated voltage
    voltage assigned to the appliance by the manufacturer
    [IEC 60335-1, ed. 4.0 (2001-05)]

    rated voltage
    quantity value assigned, generally by the manufacturer, for a specified operating condition of a machine
    [IEC 60034-18-41, ed. 1.0 (2006-10)]

    rated voltage
    input or output supply voltage for which equipment is designed or specified
    [IEC 88528-11, ed. 1.0 (2004-03)]

    rated voltage
    specified value of the voltage at the terminals of the machine when operating at a rating. If unidirectional, the voltage is the arithmetic mean of the recurring waveform and if alternating it is the root mean square value of the fundamental frequency component of the recurring waveform
    NOTE - In the case of a machine with a protective resistor permanently in series, the resistor is considered as an integral part of the machine
    [IEC 60349-1, ed. 1.0 (1999-11)]

    rated voltage
    the value of voltage assigned by the manufacturer to a component, device or equipment and to which operation and performance characteristics are referred
    NOTE - Equipment may have more than one rated voltage value or may have a rated voltage range.
    [IEC 62497-1, ed. 1.0 (2010-02)]

    rated voltage
    reference voltage for which the cable is designed, and which serves to define the electrical tests
    NOTE 1 - The rated voltage is expressed by the combination of two values: Uo/U expressed in volts (V):
    Uo being the r.m.s. value between any insulated conductor and "earth" (metal covering of the cable or the surrounding medium);
    U being the r.m.s. value between any two phase conductors of a multicore cable or of a system of single-core cables.
    In an alternating-current system, the rated voltage of a cable is at least equal to the nominal voltage of the system for which it is intended.
    This condition applies both to the value Uo and to the value U.
    In a direct current system, the nominal voltage of the system is not higher than 1,5 times the rated voltage of the cable.
    NOTE 2 - The operating voltage of a system may permanently exceed the nominal voltage of such a system by 10 %. A cable can be used at a 10 % higher operating voltage than its rated voltage if the latter is at least equal to the nominal voltage of the system
    [IEC 60245-1, ed. 4.0 (2003-12)]

    rated voltage
    highest allowable voltage between the conductors in a twin and multi conductor cable, or between one conductor and an electrical conductive screen, or between the two ends of a single core cable, or earth in unscreened cables
    [IEC 60800, ed. 3.0 (2009-07)]

    rated voltage
    the r.m.s. line-to-line voltage under rated conditions
    Primary side of input transformer: ULN
    Converter input: UVN
    Converter output: UaN
    Motor voltage: UAN
    [IEC 61800-4, ed. 1.0 (2002-09)]

    rated voltage
    input or output voltage (for three-phase supply, the phase-to-phase voltage) as declared by the manufacturer
    [IEC 62040-1, ed. 1.0 (2008-06)]

    nominal voltage, Un
    voltage by which a system is designated or identified
    [IEC 61000-4-30, ed. 2.0 (2008-10)]

    FR

    tension assignée
    tension attribuée à l'appareil par le fabricant
    [IEC 60335-1, ed. 4.0 (2001-05)]

    tension nominale
    tension assignée, généraleme<>value of voltage assigned by the manufacturer, to a componentnt par le constructeur pour des conditions spécifiées de fonctionnement de la machine
    [IEC 60034-18-41, ed. 1.0 (2006-10)]

    tension assignée
    tension spécifiée aux bornes de la machine quand celle-ci fonctionne au régime assigné. Dans le cas d'une tension redressée, sa valeur est égale à la valeur moyenne de l'onde périodique. Dans le cas d'une tension alternative, sa valeur est égale à la valeur efficace de la composante fondamentale de l'onde périodique
    NOTE - Dans le cas d'une machine équipée d'une résistance de protection connectée en permanence en série, la résistance est considérée comme faisant partie intégrante de la machine
    [IEC 60349-1, ed. 1.0 (1999-11)]

    tension assignée
    valeur de la tension, assignée par le constructeur à un composant, à un dispositif ou à un matériel, et à laquelle on se réfère pour le fonctionnement et pour les caractéristiques fonctionnelles
    NOTE - Les matériels peuvent avoir plusieurs valeurs ou une plage de tensions assignées.
    [IEC 62497-1, ed. 1.0 (2010-02)]

    tension assignée
    tension de référence pour laquelle le conducteur ou le câble est prévu et qui sert à définir les essais électriques
    NOTE 1 - La tension assignée est exprimée par la combinaison de deux valeurs Uo /U, exprimées en volts (V):
    Uo étant la valeur efficace entre l'âme d'un conducteur isolé quelconque et la «terre» (revêtement métallique du câble au milieu environnant);
    U étant la valeur efficace entre les âmes conductrices de deux conducteurs de phase quelconques d'un câble multiconducteur ou d'un système de câbles monoconducteurs ou de conducteurs.
    Dans un système à courant alternatif, la tension assignée d'un conducteur ou d’un câble est au moins égale à la tension nominale du système pour lequel il est prévu.
    Cette condition s'applique à la fois à la valeur Uo et à la valeur U.
    Dans un système à courant continu, la tension nominale admise du système n’est pas supérieure à 1,5 fois la tension assignée du conducteur ou du câble.
    NOTE 2 - La tension de service d'un système peut en permanence dépasser la tension nominale dudit système de 10 %. Un conducteur ou un câble peut être utilisé à une tension de service supérieure de 10 % à sa tension assignée si cette dernière est au moins égale à la tension nominale du système
    [IEC 60245-1, ed. 4.0 (2003-12)]

    tension assignée
    tension maximale admissible entre les âmes dans un câble ayant une paire ou multi conducteur ou entre une âme et un écran conducteur électrique ou avec la terre pour un câble non écranté ou encore entre les deux extrémités d’un câble à âme unique
    [IEC 60800, ed. 3.0 (2009-07)]

    tension assignée
    valeur efficace de la tension de ligne (entre phases) dans les conditions assignées
    Primaire du transformateur d’entrée: ULN
    Entrée du convertisseur: UVN
    Sortie du convertisseur: UaN
    Moteur: UAN
    [IEC 61800-4, ed. 1.0 (2002-09)]

    tension assignée
    tension d’alimentation d’entrée ou de sortie (dans le cas d’une alimentation triphasée, tension entre phases) déclarée par le constructeur
    [IEC 62040-1, ed. 1.0 (2008-06)]

    tension nominale, Un
    tension par laquelle un réseau est désigné ou identifié
    [IEC 61000-4-30, ed. 2.0 (2008-10)]

    Тематики

    Синонимы

    • Un

    EN

    FR

    Франко-русский словарь нормативно-технической терминологии > Un

  • 6 conditions anormales

    1. аномальные условия (работы)

     

    аномальные условия (работы)
    -

    EN

    abnormal conditions
    conditions which may occur in the appliance or in the switch during normal operation
    [IEC 61058-1, ed. 3.0 (2000-07)]

    abnormal conditions of operation
    operating conditions of low occurrence (typical only a few times during equipment lifetime)
    NOTE These include human errors, loss of power supply, overvoltages, earthquake, etc. After such a condition has occurred, equipment inspection may be required.
    [IEC 61936-1, ed. 2.0 (2010-08)]

    FR

    conditions anormales
    conditions qui peuvent se présenter dans l’appareil ou dans l'interrupteur durant une manoeuvre normale
    [IEC 61058-1, ed. 3.0 (2000-07)]

    conditions anormales de fonctionnement
    conditions de fonctionnement rares (seulement quelques fois au cours de la vie du matériel)
    NOTE Cela inclut les erreurs humaines, pertes d’alimentation, surtensions, séismes, etc. Après de telles conditions d'exploitation, une inspection de ces matériels peut être exigée.
    [IEC 61936-1, ed. 2.0 (2010-08)]

    Тематики

    EN

    FR

    Франко-русский словарь нормативно-технической терминологии > conditions anormales

  • 7 conditions anormales de fonctionnement

    1. аномальные условия (работы)

     

    аномальные условия (работы)
    -

    EN

    abnormal conditions
    conditions which may occur in the appliance or in the switch during normal operation
    [IEC 61058-1, ed. 3.0 (2000-07)]

    abnormal conditions of operation
    operating conditions of low occurrence (typical only a few times during equipment lifetime)
    NOTE These include human errors, loss of power supply, overvoltages, earthquake, etc. After such a condition has occurred, equipment inspection may be required.
    [IEC 61936-1, ed. 2.0 (2010-08)]

    FR

    conditions anormales
    conditions qui peuvent se présenter dans l’appareil ou dans l'interrupteur durant une manoeuvre normale
    [IEC 61058-1, ed. 3.0 (2000-07)]

    conditions anormales de fonctionnement
    conditions de fonctionnement rares (seulement quelques fois au cours de la vie du matériel)
    NOTE Cela inclut les erreurs humaines, pertes d’alimentation, surtensions, séismes, etc. Après de telles conditions d'exploitation, une inspection de ces matériels peut être exigée.
    [IEC 61936-1, ed. 2.0 (2010-08)]

    Тематики

    EN

    FR

    Франко-русский словарь нормативно-технической терминологии > conditions anormales de fonctionnement

  • 8 parafoudre à oxyde métallique sans éclateur

    1. ограничитель перенапряжений

     

    ограничитель перенапряжений нелинейный
    ОПН

    Аппарат, предназначенный для защиты изоляции электрооборудования от грозовых и коммутационных перенапряжений, представляющий собой последовательно и/или параллельно соединенные металлооксидные варисторы без каких-либо последовательных или параллельных искровых промежутков, заключенные в изоляционный корпус
    [ ГОСТ Р 52725-2007]

    EN

    metal-oxide surge arrester without gaps
    arrester having non-linear metal-oxide resistors connected in series and/or in parallel without any integrated series or parallel spark gaps
    [IEC 60099-4, ed. 2.0 (2004-05)]

    FR

    parafoudre à oxyde métallique sans éclateur
    parafoudre à résistances variables à oxyde métallique connectées en série et/ou en parallèle, ne comportant pas d'éclateurs en série ou en parallèle
    [IEC 60099-4, ed. 2.0 (2004-05)]

    В электрических сетях часто возникают импульсные всплески напряжения, вызванные коммутациями электроаппаратов, атмосферными разрядами или иными причинами. Несмотря на кратковременность такого перенапряжения, его может быть достаточно для пробоя изоляции и, как следствие, короткого замыкания, приводящего к разрушительным последствиям.Для того, чтобы устранить вероятность короткого замыкания, можно применять более надежную изоляцию, но это приводит к значительному увеличению стоимости оборудования. В связи с этим в электрических сетях целесообразно применять разрядники.
    Ограничитель перенапряжения нелинейный (ОПН) — это элемент защиты без искровых промежутков. Активная часть ОПН состоит из легированного металла, при подаче напряжения он ведет себя как множество последовательно соединенных варисторов. Принцип действия ОПН основан на том, что проводимость варисторов нелинейно зависит от приложенного напряжения. При отсутствии перенапряжений ОПН не пропускает ток, но как только на участке сети возникает перенапряжение, сопротивление ОПН резко снижается, чем и обуславливается эффект защиты от перенапряжения. После окончания действия перенапряжения на выводах ОПН, его сопротивление опять возрастает. Переход из «закрытого» в «открытое» состояние занимает единицы наносекунд (в отличие от разрядников с искровыми промежутками, у которых это время срабатывания может достигать единиц микросекунд). Кроме высокой скорости срабатывания ОПН обладает еще рядом преимуществ. Одним из них является стабильность характеристики варисторов после неоднократного срабатывания вплоть до окончания указанного времени эксплуатации, что, кроме прочего, устраняет необходимость в эксплуатационном обслуживании

    0706

    На электрических принципиальных схемах в России разрядники обозначаются согласно ГОСТ 2.727—68.
    1. Общее обозначение разрядника
    2. Разрядник трубчатый
    3. Разрядник вентильный и магнитовентильный
    4. ОПН

    [http://ru.wikipedia.org/wiki/%D0%9E%D0%9F%D0%9D]

    Параллельные тексты EN-RU

    Surge arresters

    To limit the occurrence of over voltages, an over voltage arrester is available upon request.

    The encapsulated surge arrester is designed on the basis of metallic oxide conductive resistors.

    These blow out if there is an overload, and the system protection turns off the faulty electrical circuit in a controlled manner.

    The surge arrester is in single-pole design.

    It has its own enclosure sealed by a sealed bushing.

    Connections for equipment to monitor the arrester.


    [Siemens]

    Ограничитель перенапряжений

    По запросу КРУЭ оснащается ограничителями перенапряжений.

    Ограничитель перенапряжений выполнен на базе металлооксидных варисторов и помещен в оболочку.

    При возникновении перенапряжения варисторы переходят в проводящее состояние, в результате чего система защиты отключает неисправную электрическую цепь.

    Ограничитель перенапряжений выполнен в виде однополюсного модуля.

    Ограничитель имеет собственную оболочку, герметично закрытую проходным изолятором.

    Ограничитель перенапряжений имеет выводы для подключения приборов контроля его состояния.


    [Перевод Интент]

    The GIS lay out in option of zinc oxide lightning arrester under metal enclosure insulated with gas SF6.

    The zinc oxide lightning arrester earths currents of considerable amplitude injected by accidental phenomena: lightning and operating overvoltages.

    The non-linear resistance of the zinc oxide maintains a residual voltage lower than the GIS insulation voltage during the flow of high currents.

    An impulse counter records the number of times high current passes through the conductor and the maximum amplitude attained.


    [Siemens]

    В КРУЭ может быть установлен ограничитель перенапряжений, выполненный на основе оксидноцинковых варисторов, размещенных в металлической оболочке, заполненной элегазом.

    Оксидноцинковый ограничитель перенапряжений отводит на землю значительные по амплитуде токи, которые могут появиться в результате атмосферных и коммутационных перенапряжений.

    При протекании значительного тока значение поддерживаемого нелинейным оксидноцинковым варистором остающегося напряжения ниже напряжения изоляции КРУЭ.

    Отдельный счетчик подсчитывает каждый проход тока через ограничитель и его амплитуду.


    [Перевод Интент]

    Transport and storage

    Lightning arresters are filled with SF6 or nitrogen gas under pressure in the factory.

    They are also fitted with a moisture filter.

    Maintain the lightning arrester in a vertical position during transport and storage.


    [Siemens]

    Транспортирование и хранение

    Ограничители перенапряжений
    заправлены на заводе-изготовителе элегазом или азотом под давлением.

    Ограничители оснащены фильтром-осушителем.

    При транспортировании и хранении ограничители перенапряжений должны находиться в вертикальном положении.


    [Перевод Интент]

     

    Недопустимые, нерекомендуемые

    Примечание(1)- Мнение автора карточки

    Тематики

    Синонимы

    EN

    FR

    Франко-русский словарь нормативно-технической терминологии > parafoudre à oxyde métallique sans éclateur

См. также в других словарях:

  • Operating system — Operating systems …   Wikipedia

  • Operating Industries Inc., Landfill — Superfund site Geography City Monterey Park County Los Angeles County State California …   Wikipedia

  • Operating surplus — is an accounting concept used in national accounts statistics (such as United Nations System of National Accounts (UNSNA) and in corporate and government accounts. It is the balancing item of the Generation of Income Account in the UNSNA. It may… …   Wikipedia

  • Times Roman — Category Serif Classification Transitional Designer(s) Victor Lardent Comm …   Wikipedia

  • Operating room management — An operating theatre (gynecological hospital of Medical University of Silesia in Bytom) Operating room management is the science of how to run an Operating Room Suite. Operational operating room management focuses on maximizing operational… …   Wikipedia

  • Operating leverage — Sachin Jadhav explained the Definition of Operating Levarage as, The operating leverage is a measure of how revenue growth translates into growth in operating income. It is a measure of leverage, and of how risky (volatile) a company s operating… …   Wikipedia

  • Operating temperature — An operating temperature is the temperature at which an electrical or mechanical device operates. The device will operate effectively within a specified temperature range which varies based on the device function and application context, and… …   Wikipedia

  • Operating Thetan — In Scientology, the state of Operating Thetan (OT) is a spiritual state above Clear. L. Ron Hubbard, the founder of Scientology, defined it as knowing and willing cause over life, thought, matter, energy, space and time (MEST) .[1] According to… …   Wikipedia

  • Operating lease — Short term, cancelable lease. A type of lease in which the period of contract is less than the life of the equipment and the lessor pays all maintenance and servicing costs. The New York Times Financial Glossary * * * operating lease operating… …   Financial and business terms

  • Times Square (Hong Kong) — infobox shopping mall shopping mall name = Times Square caption = location = Causeway Bay, Hong Kong opening date = April 1994 developer= The Wharf (Holdings) Limited manager = The Wharf (Holdings) Limited owner = The Wharf (Holdings) Limited… …   Wikipedia

  • Times Record News — Type Daily newspaper Format Broadsheet Owner The E.W. Scripps Company Publisher Dwayne Bivona …   Wikipedia

Поделиться ссылкой на выделенное

Прямая ссылка:
Нажмите правой клавишей мыши и выберите «Копировать ссылку»